Chennai
+919382206047

'ir foot temperature measurement'

Items tagged with 'ir foot temperature measurement'

product image
Pain & Woundcare Products

Neurostim is a drug free, painless answer to eliminating pain and burning sense. The Neurostim works by stimulating all your nerves from your lower back down to your toes with a specific gentle waveform that your peripheral nerves naturally use to communicate with the rest of your body. The Neurostim opens your nerve paths to restore full function. All other devices temporarily treat only pain; the Neurostim permanently eliminates pain. • Relieves Your Pain and Numbness • Helps You Sleep All Night • Restores Your Balance and Mobility • Restores Feeling in Feet and Hands • Reduces or Eliminates Pain Medications The NeuroStim has proven to be highly effective in treating a number of conditions, such as: • Diabetic Nerve Pain • Peripheral Neuropathy • Diabetic Peripheral Neuropathy • Carpal Tunnel Syndrome • Chronic Inflammatory Demyelinating polyneuropathy • Muscle Spasms • Peripheral Arterial Disease • Venous Stasis • Stroke Rehabilitation • Symptoms Related to Lymph Disease • Symptoms Related to Chronic Fatigue Syndrome

Send Message
product image
Diabetic Foot Evaluation Lab

Our All-in-one Complete Diabetic Foot Lab model DIABETIK MINILAB is our one of the best products that can measure and document all the important parameters such as the Ankle Brachial Index(ABI), Toe Brachial Index(TBI), Doppler Waveform, Monofilament 10gm, Biothesiometry, Foot Pressure and Foot Temperature. In addition to the above reports, a master report is created by the software will capture the medical history with symptoms of the patient, dermatological exam, musculoskeletal exam, vascular and footwear exams along with the recorded test results and their interpretations. A colorful 6 pages report is generated by the software. The Diabetik Minilab is supplied with all the accessories and a sturdy trolley. An all-in-one scanner/copier/printer of a particular specification is supplied with the device. A Windows 7/8/10 operated laptop is to be arranged by the buyer. Vascular Screening: Whenever one suspects Peripheral Arterial Disease (PAD), the clinician must perform a few non-invasive vascular testing methods that are commercially available and widely implemented. Features: • Unidirectional 8MHz probe • Photo-plethysmograph PPG Toe sensor • BP cuffs for ABI/TBI • Ankle Brachial Index (ABI) • Toe Brachial Index (TBI) • Doppler Velocity Waveform • Venous Examination (No documentation) • Carotid, Penile examination (No documentation) Neuropathy Screening: Diabetes can result in long-term health complications, with one of the most common being microvascular damage that leads to diabetic neuropathy (DN), which affects multiple body systems and increases amputation risk. A typical form of DN is diabetic peripheral neuropathy (DPN), which is known to be a primary cause of balance issues, and sensation loss in the feet, and a major contributor to nontraumatic lower-limb amputations. Loss of sensation in the foot can be diagnosed with a 10gm Monofilament and a Biothesiometry. Semmes‐Weinstein monofilament test (SWMT): The SWMT is a common screening tool for assessing the sensory function and the loss of pressure sensation (light touch perception). A 10-gm monofilament test (also referred to as the 5.07 monofilament) is the most common in practice. 25 Nos of such monofilament in a box are supplied with the device. The filament is applied to at least six sites on the foot until it buckles, which occurs at 10 g of linear pressure when the patient is asked to detect its presence. If it is not detected on at least four out of six sites, then the protective sensation is considered to be lost. Biothesiometry: Vibration perception threshold (VPT) has been shown to be strongly associated with foot ulceration. VPT determination by using a Digital Biothesiometer has been used to identify peripheral sensory neuropathy and subjects at risk of the foot. Digital Biothesiometer helps us quantitate the threshold and monitor progressive changes or trends on following up testing. Sensory neuropathy increases the risk of foot ulcerations by seven-fold and peripheral arterial disease (PAD) by three folds in people with diabetes. Peripheral neuropathy is the major causal factor in the development of foot ulcerations among diabetic subjects. Early detection of vibration perception threshold (VPT) helps better prevention. Prevention is better than no cure. 50% of all non-traumatic amputations occur in diabetes which is a high-risk group. . Features: • First Company to introduce Digital Biothesiometry in India - 2003 • Digital 0 to 50 Volts indicator • Vibrator with Mute/Check & Record key • Full solid-state design Plantar Pressure measurement: Understanding foot biomechanics is an important component in the evaluation of diabetic foot. The abnormal plantar pressure distribution plays a key role in the formation of plantar calluses and diabetic foot ulcers. Abnormal value of foot pressure, as well as neuropathy, could play an important role in the formation of plantar ulcers independently. Current international guidelines advocate achieving at least a 30 % reduction in maximum plantar pressure to reduce the risk of foot ulcers in people with diabetes. Features: • Foot Imprinter Harris Mat FM1111 • Licensed software to scan and image process FM1111 foot image. • Report to include the footwear measurements. • Multi-color picture image indicates the pressure mapping. IR Foot Temperature measurement: Monitoring of skin temperatures at the foot, along with subsequent offloading can dramatically reduce the occurrence of ulcerations. The defined threshold reported in numerous studies is an asymmetrical difference of 4ºF (2.2°C) between the sites. Because most patients at risk for ulceration are also at risk for Charcot, monitoring foot temperature would be an effective tool. Features: • Simple one-handed operation • Laser targeting • oC / oF select switch, Accuracy +/- 2% • Early marker for Charcot foot • Can reduce the risk of ulceration.

Send Message
product image
Diabetic Foot Evaluation Lab

Automated diabetic foot evaluation lab model Diabetik Autolab is capable of screening (1) Vascular Insufficiencies using Ankle Brachial Index, Toe Brachial Index, Velocity waveform analysis, (2) Diabetic neuropathy using loss of vibration perception threshold (VPT)-Biothesiometry and loss of protective touch sense-Monofilament 10gm, (3) plantar pressure screening using advance electronic sensor platform by checking static(weight bearing), dynamic(walking) and postural imbalance, (4) Non-contact measurement of temperature in the foot for early assessment of inflammation in the foot. A master report is generated with the patients clinical information, medical information and the measured data with interpretation. Device is supplied in a trolley and a branded i3 based laptop computer and an EPSON ink tank printer. Sales and service team across India to train the user periodically. ISO13485:2016 certified company.

Send Message
product image
Plantar Pressure Measurement Systems

• Measure static, dynamic, multi-dynamic and postural pressure mapping • Bi-directional walking facility • Sensor size of 8 x 8 mm • 400mm x 400mm sensing area • 1600 sensors with Sampling rate 100Hz • Maximum of 200kg patient load • Maximum Pressure 100N/cm2 • Weighs 3.15 kg • Dimension of 565mm(L) x 612(D) x 22mm – 7mm(H) • Thickness of platform 7mm or less • Displays area, Maximum Pressure curves • Should have storage of measurement data • Displays each frame in rollover process (ROP) • Displays maximum pressure picture (MPP) • Displays of % of the distribution of pressure • Force value graph display for both foot • Prints screen copy • Prints 1:1 actual size • Displays centre of pressure (COP) line • Connects to PC through USB for data transfer and power • Software compatible to any Windows Computer • Displays 60 frames of mosaic for one measurement • 2D and 3D pressure display • Provision to connect a video camera • Video walking synchronized with pressure rollover is available • Comparison of videos of patients walking • Comparison of reports of the same patient or with multi-patient • Export of data available • Facility for data backup and retrieval • PDF printing facility • Branded computer with processor i3 or above and color printer (Optional)

Send Message
product image
Plantar Pressure Measurement Systems

Deformity due to the diabetic foot causes repetitive and excessive pressure to certain areas of the foot, which may result in ulcers and pains. Therefore, it is necessary to measure the pressure of the sole for the prevention and management of diabetic foot lesions. Early identification of feet 'at risk' for ulceration is important in preventing plantar lesions in diabetic patients with insensitive feet. Plantar pressures are higher in diabetic neuropathic patients than non-diabetic and non-neuropathic Counterparts. As high plantar pressure is a proven risk factor for foot ulceration, effective screening for high plantar pressures in diabetic patients could have a major influence on the incidence of diabetic foot ulceration. High plantar foot pressure has been identified as a significant risk factor for ulcerations. A large number of studies have suggested that plantar pressures are high in people with diabetic peripheral neuropathy (DPN) and in people with a history of diabetic foot ulcers. Measurement of these foot pressures is possible utilizing a variety of modalities. Several computerized systems can provide quantitative measurement of plantar foot pressure. These measurements are important in identifying areas of the foot at risk for ulceration and possibly in the evaluation of orthotic adjustments. In order to identify high-risk patients in a clinical setting, a simple system for screening is needed which is easy to use, reliable and gives results that are easy to interpret and can be immediately available to both the patient and staff. Our Foot Imprinter Harris Mat FM1111 has been developed as a simple, inexpensive and practical foot pressure measurement device intended for routine clinical use. It is a semiquantitative footprint mat that quantifies plantar pressure by visual comparison between the greyness of the footprint. Features: • Measures and display patient weight disbursement in greyscale • Detects the area of the greatest concern for ulceration • Useful to identify Charcot arthropathy • Arch of the patient can be detected • More the darker color represent the high pressure • Excellent tool for motivating the patient to upgrade to a good footwear • Kit includes FI1111 mat, rubber roller, ink pad, Ink and prescription pad

Send Message
product image
Neuropathy Screening Products

VibraTip a wipe-clean, pocket-sized and disposable device for testing vibration sense. Vibration sense is typically one of the first sensory modalities to be impaired as peripheral neuropathy develops. Graduated tuning forks (e.g. Reidel-Seiffer) and calibrated electronic devices (e.g. Neurothesiometer, Bio-Thesiometer Vibrometer) are recommended to quantify the integrity of vibration sensation. VibraTip is a wipe-clean, disposable, key fob-sized device that provides a constant and reproducible source of vibration. The spherical head facilitates application from any angle and its pocket size means that it is easy to carry and therefore likely to be available at the point of use.

Send Message
product image
Vascular Screening Products

DFCI offers a full-featured automated ABI/TBI Vascular System for the diagnosis of PAD. ABI/TBI/PVR/Segmental Doppler/Upper extremity/Carotid Doppler/Penile Doppler/Venous Doppler are the different modalities possible with this model. The system includes 6 pressure cuffs, a graphic waveform LCD display, automatic cuff inflation and deflation along with automatic indices calculation. PC software and USB connectivity are included for storage and performing the standard protocols. Features:- • Automatic ABI, TBI, PVR and segmental measurement • Automatic cuff inflation and deflation system • Guided step by step protocol • Large graphic LCD display • Uni-Directional 8 MHz Doppler Probe • PVR waveform • Photoplethysmography PPG Toe Sensor for TBI • Special Toe cuff is supplied • Separate mode for complete vascular profile study • Penile flow study • Gets connected on to any computer • Standards matching the International specification • Software for patient report generation & storage.

Send Message
product image
Vascular Screening Products

The handheld Unidirectional ultrasound vascular Doppler is an instrument that detects blood flow using the principles of the Doppler effect. It can be a very useful tool in assessing how good the blood flow is to the foot or hand. It is a painless test and very similar to taking blood pressure using a stethoscope. It is particularly useful for the assessment of arterial disease but can also be used for venous problems. These vascular Doppler are used for identifying the arterial and venous flow patency. Ankle Brachial Index (ABI) is a simple procedure to detect obstruction in the blood flow. The LifeDop 150R features a non-display, handheld Doppler with superior sound quality, extended battery life, enhanced probe sensitivity, interchangeable probes, and a one-year full warranty. It includes a battery recharging system, so you don’t have to worry about overcharging or draining of the batteries. Features: • Interchangeable Doppler Probes • Unidirectional Doppler • 8MHz Vascular Probe is Standard • Continuous Wave Doppler • 4, 5 and 8 MHz Vascular probes • Rechargeable battery operation • Charger supplied free

Send Message
product image
Diabetic Neuropathy Products

Peripheral neuropathy is the prime cause of diabetic foot ulceration. Ulceration, in turn, is the key factor that may precipitate a cascade of events leading to lower-extremity amputation. Checking the loss of Thermal Sense, Vibration sense and protective Touch Sense will help the management of diabetic neuropathy and its effect on the foot. Three important simple devices are packaged in the Neuropathy Assessment Kit (NA03) for the effective management of diabetic neuropathy. The kit contains a Tiptherm, a Vibratip and Monofilament 10gm(25 Nos). TIP THERM® is a simple device for the early diagnosis of symmetrical polyneuropathy by measuring the loss of temperature sensitivity of the skin. TIP THERM® was developed to give the clinician and patient a convenient and easy-to-use method of testing. This device is recommended to use, at a room temperature of 23° C. Failure to perceive variances in temperature in the extremities is the most decisive early symptom of distal symmetric polyneuropathy, a typical ailment accompanying diabetes mellitus (Ziegler 1988). Portable Vibration sense device VIBRATIPTM is a device resembling a small key fob that provides a near-silent vibration of consistent amplitude at a frequency similar to that of a calibrated tuning fork. It is intended for use when testing a person’s vibration perception during routine checks for diabetic peripheral neuropathy (DPN) in people who have type 1 or type 2 diabetes. It is a disposable device works for about 250 patients, and vibrates at 125 Hz with an intensity equivalent to that of a Biothesiometer at 25 Volts. When the patient does not feel the vibration is classified as a high-risk category. MF10GM: Monofilaments 10gm is an effective, convenient, easy to use, relatively inexpensive way of testing for loss of protective touch sense in the feet. It is designed for single-patient use and can be used till 100 bends or filament damage.

Send Message

Still searching for
ir foot temperature measurement?