Chennai
+919382206047

'emi emc'

Items tagged with 'emi emc'

product image
Vascular Screening Products

Vasochek+ is a complete non-invasive unidirectional vascular doppler recorder designed to measure the ABI, TBI and the velocity waveform with a connection to a windows 7/8/10 operated computer for storage of data and patient report generation. Interpretation as per TASC II guidelines. FEATURES: • Ankle Brachial Index and Toe Brachial Index • Doppler (C.W) with 8MHz Transducer • Photo-Plethysmography (PPG) Toe sensor • Semi-automated system • Software for ABI/TBI with Waveform • Computer connectivity enabled • Software for data transfer, storage and patient report • Software supports Windows 7/8/10 • Standards matching International standards

Send Message
product image
Diabetic Neuropathy Products

Peripheral neuropathy is the prime cause of diabetic foot ulceration. Ulceration, in turn, is the key factor that may precipitate a cascade of events leading to lower-extremity amputation. Checking the loss of Thermal Sense, Vibration sense and protective Touch Sense will help the management of diabetic neuropathy and its effect on the foot. Three important simple devices are packaged in the Neuropathy Assessment Kit (NA03) for the effective management of diabetic neuropathy. The kit contains a Tiptherm, a Vibratip and Monofilament 10gm(25 Nos). TIP THERM® is a simple device for the early diagnosis of symmetrical polyneuropathy by measuring the loss of temperature sensitivity of the skin. TIP THERM® was developed to give the clinician and patient a convenient and easy-to-use method of testing. This device is recommended to use, at a room temperature of 23° C. Failure to perceive variances in temperature in the extremities is the most decisive early symptom of distal symmetric polyneuropathy, a typical ailment accompanying diabetes mellitus (Ziegler 1988). Portable Vibration sense device VIBRATIPTM is a device resembling a small key fob that provides a near-silent vibration of consistent amplitude at a frequency similar to that of a calibrated tuning fork. It is intended for use when testing a person’s vibration perception during routine checks for diabetic peripheral neuropathy (DPN) in people who have type 1 or type 2 diabetes. It is a disposable device works for about 250 patients, and vibrates at 125 Hz with an intensity equivalent to that of a Biothesiometer at 25 Volts. When the patient does not feel the vibration is classified as a high-risk category. MF10GM: Monofilaments 10gm is an effective, convenient, easy to use, relatively inexpensive way of testing for loss of protective touch sense in the feet. It is designed for single-patient use and can be used till 100 bends or filament damage.

Send Message
product image
Podiatry Products

The Durometer is commonly also known as Shore Meter. There are two variants in this Shore Meter. They are Shore Meter A and Shore meter D. Shore durometer A is a device for measuring the hardness of soft material, typically of polymers, elastomers, and rubbers. Shore Meter D is mainly for hard materials like plastics, steel etc., We are distributing Shore Meter A and all the discussions and descriptions are about them only. Higher numbers on the scale indicate a greater resistance to indentation and thus harder materials. Lower numbers indicate less resistance and softer materials. Durometer measurement scales range from 0 to 100 and simply represent a relative comparison of hardness difference. The durometer has shown consistent reliability in the objective assessment of skin hardness in patients with systemic sclerosis and localized scleroderma. It is an easy-to-use and simple method, which can provide a correct numeric evaluation of hypertrophic scars induration and objective control of therapeutic efficacy during treatment over time. Determination of skin hardness by this instrument has been proven to be accurate and reproducible, both in normal and pathological conditions. Increased foot sole hardness and peripheral neuropathy are suggested to be important risk factors for foot ulceration. In subjects with diabetes, it was found in numerous research that differences and variations in foot sole hardness were found to be significantly different in subjects with and without diabetic neuropathy using Durometer (Shore meter). Hence shore meter was more sensitive and provided a feasible means of measuring foot sole hardness in subjects with diabetic neuropathy. Foot sole hardness in diabetic feet can be considered as a potential determinant of foot sole ulcerations. The durometer has potential use in many dermatological disorders as a tool to be used routinely to demonstrate improvement in treatment, particularly in burn patients where cosmetic appearance and functional status represent major concerns for the patient.

Send Message
product image
Plantar Pressure Measurement Systems

Deformity due to the diabetic foot causes repetitive and excessive pressure to certain areas of the foot, which may result in ulcers and pains. Therefore, it is necessary to measure the pressure of the sole for the prevention and management of diabetic foot lesions. Early identification of feet 'at risk' for ulceration is important in preventing plantar lesions in diabetic patients with insensitive feet. Plantar pressures are higher in diabetic neuropathic patients than non-diabetic and non-neuropathic Counterparts. As high plantar pressure is a proven risk factor for foot ulceration, effective screening for high plantar pressures in diabetic patients could have a major influence on the incidence of diabetic foot ulceration. High plantar foot pressure has been identified as a significant risk factor for ulcerations. A large number of studies have suggested that plantar pressures are high in people with diabetic peripheral neuropathy (DPN) and in people with a history of diabetic foot ulcers. Measurement of these foot pressures is possible utilizing a variety of modalities. Several computerized systems can provide quantitative measurement of plantar foot pressure. These measurements are important in identifying areas of the foot at risk for ulceration and possibly in the evaluation of orthotic adjustments. In order to identify high-risk patients in a clinical setting, a simple system for screening is needed which is easy to use, reliable and gives results that are easy to interpret and can be immediately available to both the patient and staff. Our Foot Imprinter Harris Mat FM1111 has been developed as a simple, inexpensive and practical foot pressure measurement device intended for routine clinical use. It is a semiquantitative footprint mat that quantifies plantar pressure by visual comparison between the greyness of the footprint. Features: • Measures and display patient weight disbursement in greyscale • Detects the area of the greatest concern for ulceration • Useful to identify Charcot arthropathy • Arch of the patient can be detected • More the darker color represent the high pressure • Excellent tool for motivating the patient to upgrade to a good footwear • Kit includes FI1111 mat, rubber roller, ink pad, Ink and prescription pad

Send Message
product image
Neuropathy Screening Products

Failure to perceive variances in temperature in the extremities is the most decisive early symptom of distal symmetric polyneuropathy, a typical ailment accompanying diabetes mellitus (Ziegler 1988). Small-fiber Test (HCP) provides an easy-to-use and scientifically validated measure of warm, cool and heat pain thermal sensory thresholds, all clinically useful determinants in the evaluation of diabetic neuropathy. Vibration Perception Threshold (VPT) has been shown to be strongly associated with foot ulceration. VPT determination by using a Digital Biothesiometer has been used to identify peripheral sensory neuropathy and subjects at risk of the foot. Digital Biothesiometer helps us quantitate the threshold and monitor progressive changes or trends on following up testing. Sensory neuropathy increases the risk of foot ulcerations by seven-folds and peripheral arterial disease (PAD) by three folds in people with diabetes. Peripheral neuropathy is the major causal factor in the development of foot ulcerations among diabetic subjects. Early detection helps better prevention. Prevention is better than no cure. 50% of all non-traumatic amputations occur in diabetes who is a high-risk group. Our Neuropathy Analyser model Vibrotherm Dx has inbuilt both VPT and HCP in a single device. The Windows 7/8/10 supported software supplied helps to capture the VPT, COLD, HOT and Monofilament 10gm testing for storage and a patient report. FEATURES: • Full solid-state design with PC enabled • Easy Tool to quantify Neuropathy • Digital Biothesiometer VPT and Thermometry HCP combined • Digital 0 ~ 50 Volts Vibration output • 1 ~ 50o C temperature output range • 1o C rate of change per second • Remote keypad helps easy operation • Single probe delivers both Hot & Cold temperatures • Automatic interpretation based on set reference values • Early detection of Small Fiber Neuropathy • Software supports Windows Win 7 / Win 8 / Win10 computer • Patient report storage, export, pdf options available • USB interface

Send Message
product image
Neuropathy Screening Products

This basic neuropathy Assessment kit consists of one Tiptherm, one VibraTip and 25 Nos. 10gm Monofilaments to check the loss of temperature, vibration and touch sensitivity. Early diagnosis of distal symmetric polyneuropathy by testing temperature sensitivity, can prevent complications of diabetic foot. Precious time is gained if examinations are geared towards detecting this symptom. Regular testing of temperature sensitivity should therefore be a compulsory part of basic diabetes treatment. Failure to perceive variances in temperature in the extremities is the most decisive early symptom of distal symmetric polyneuropathy, a typical ailment accompanying diabetes mellitus (Ziegler 1988). TIP THERM® is ideal for testing temperature sensitivity. It is not dependent on external power sources, is practically indestructible, easy to handle and small and light enough to fit in any jacket or overall pocket. VibraTipTM: a wipe-clean, pocket-sized and disposable device for testing vibration sense. The advantages include ease and speed of the test with little required training, less user variability compared with the calibrated tuning-fork test, small size, and easy cleaning.

Send Message
product image
Vascular Screening Products

DFCI offers a full-featured automated ABI/TBI Vascular System for the diagnosis of PAD. ABI/TBI/PVR/Segmental Doppler/Upper extremity/Carotid Doppler/Penile Doppler/Venous Doppler are the different modalities possible with this model. The system includes 6 pressure cuffs, a graphic waveform LCD display, automatic cuff inflation and deflation along with automatic indices calculation. PC software and USB connectivity are included for storage and performing the standard protocols. Features:- • Automatic ABI, TBI, PVR and segmental measurement • Automatic cuff inflation and deflation system • Guided step by step protocol • Large graphic LCD display • Uni-Directional 8 MHz Doppler Probe • PVR waveform • Photoplethysmography PPG Toe Sensor for TBI • Special Toe cuff is supplied • Separate mode for complete vascular profile study • Penile flow study • Gets connected on to any computer • Standards matching the International specification • Software for patient report generation & storage.

Send Message
product image
Plantar Pressure Measurement Systems

The Podiascan system provides podiatrists and bio-mechanists with an economical and efficient method to measure static and dynamic plantar foot pressure distribution. The Podiascan system produces instantaneous and permanent high resolution image of the pressure distribution across the planter surface. We sell this product only in India. The Harris Mat paper output is scanned and the resultant grey scale image is converted into colour scale. Features : • System consists of Harris Mat, Special Scanner Copier and Printer, Image Analysis Software and Patient Reporting Software. • Economical method to measure Static and Dynamic Plantar foot pressure. • Qualitative multi-colour output makes the pressure reading easier. Used to Identify : • Areas of potential ulceration • Pre and Post surgical evaluation • Degree of pronation or supination • Weight bearing after surgery

Send Message
product image
Neuropathy Screening Products

In diabetes mellitus, polyneuropathy is an important complication and should be diagnosed as early as possible in order to prevent damage to the patient. Determination of warm, cold, and heat pain thresholds enables one to judge small nerve fibre sensitivity. Failure to perceive variances in temperature in the extremities is the most decisive early symptom of distal symmetric polyneuropathy, a typical ailment accompanying diabetes mellitus (Ziegler 1988). The Thermometry HCP may be used on patients with neurological diseases (especially peripheral neuropathy). The system is designed to measure and store patient responses to a series of thermal stimuli, but does not make any diagnosis. The test results should be used with the results of other medically accepted tests in order to assist the physician in making a final diagnosis. The product is highly accurate and truly calibrated to produce repeatable results. When the patients are properly explained and instructed before the testing, the results of the tests are highly sensitive, specific, and quantified. Features: • Full solid state Design PC enabled • Non invasive testing of pain thresholds • Range : 10 C to 500 C (Restricted for the purpose of safety) • Rate of change : 0.50 C per second for Hot/Cold • Helps to find Cool, Warm, Hot, and Cold Perception Thresholds • Data storage on Personal Computer. • Easy operation with hand remote • Helps detecting Diabetic Polyneuropathy at an early stage

Send Message

Still searching for