Chennai
+919382206047

'valuable clinical information'

Items tagged with 'valuable clinical information'

product image
Diabetic Foot Evaluation Lab

Automated diabetic foot evaluation lab model Diabetik Autolab is capable of screening (1) Vascular Insufficiencies using Ankle Brachial Index, Toe Brachial Index, Velocity waveform analysis, (2) Diabetic neuropathy using loss of vibration perception threshold (VPT)-Biothesiometry and loss of protective touch sense-Monofilament 10gm, (3) plantar pressure screening using advance electronic sensor platform by checking static(weight bearing), dynamic(walking) and postural imbalance, (4) Non-contact measurement of temperature in the foot for early assessment of inflammation in the foot. A master report is generated with the patients clinical information, medical information and the measured data with interpretation. Device is supplied in a trolley and a branded i3 based laptop computer and an EPSON ink tank printer. Sales and service team across India to train the user periodically. ISO13485:2016 certified company.

Send Message
product image
Plantar Pressure Measurement Systems

Deformity due to the diabetic foot causes repetitive and excessive pressure to certain areas of the foot, which may result in ulcers and pains. Therefore, it is necessary to measure the pressure of the sole for the prevention and management of diabetic foot lesions. Early identification of feet 'at risk' for ulceration is important in preventing plantar lesions in diabetic patients with insensitive feet. Plantar pressures are higher in diabetic neuropathic patients than non-diabetic and non-neuropathic Counterparts. As high plantar pressure is a proven risk factor for foot ulceration, effective screening for high plantar pressures in diabetic patients could have a major influence on the incidence of diabetic foot ulceration. High plantar foot pressure has been identified as a significant risk factor for ulcerations. A large number of studies have suggested that plantar pressures are high in people with diabetic peripheral neuropathy (DPN) and in people with a history of diabetic foot ulcers. Measurement of these foot pressures is possible utilizing a variety of modalities. Several computerized systems can provide quantitative measurement of plantar foot pressure. These measurements are important in identifying areas of the foot at risk for ulceration and possibly in the evaluation of orthotic adjustments. In order to identify high-risk patients in a clinical setting, a simple system for screening is needed which is easy to use, reliable and gives results that are easy to interpret and can be immediately available to both the patient and staff. Our Foot Imprinter Harris Mat FM1111 has been developed as a simple, inexpensive and practical foot pressure measurement device intended for routine clinical use. It is a semiquantitative footprint mat that quantifies plantar pressure by visual comparison between the greyness of the footprint. Features: • Measures and display patient weight disbursement in greyscale • Detects the area of the greatest concern for ulceration • Useful to identify Charcot arthropathy • Arch of the patient can be detected • More the darker color represent the high pressure • Excellent tool for motivating the patient to upgrade to a good footwear • Kit includes FI1111 mat, rubber roller, ink pad, Ink and prescription pad

Send Message
product image
Neuropathy Screening Products

Failure to perceive variances in temperature in the extremities is the most decisive early symptom of distal symmetric polyneuropathy, a typical ailment accompanying diabetes mellitus (Ziegler 1988). Small-fiber Test (HCP) provides an easy-to-use and scientifically validated measure of warm, cool and heat pain thermal sensory thresholds, all clinically useful determinants in the evaluation of diabetic neuropathy. Vibration Perception Threshold (VPT) has been shown to be strongly associated with foot ulceration. VPT determination by using a Digital Biothesiometer has been used to identify peripheral sensory neuropathy and subjects at risk of the foot. Digital Biothesiometer helps us quantitate the threshold and monitor progressive changes or trends on following up testing. Sensory neuropathy increases the risk of foot ulcerations by seven-folds and peripheral arterial disease (PAD) by three folds in people with diabetes. Peripheral neuropathy is the major causal factor in the development of foot ulcerations among diabetic subjects. Early detection helps better prevention. Prevention is better than no cure. 50% of all non-traumatic amputations occur in diabetes who is a high-risk group. Our Neuropathy Analyser model Vibrotherm Dx has inbuilt both VPT and HCP in a single device. The Windows 7/8/10 supported software supplied helps to capture the VPT, COLD, HOT and Monofilament 10gm testing for storage and a patient report. FEATURES: • Full solid-state design with PC enabled • Easy Tool to quantify Neuropathy • Digital Biothesiometer VPT and Thermometry HCP combined • Digital 0 ~ 50 Volts Vibration output • 1 ~ 50o C temperature output range • 1o C rate of change per second • Remote keypad helps easy operation • Single probe delivers both Hot & Cold temperatures • Automatic interpretation based on set reference values • Early detection of Small Fiber Neuropathy • Software supports Windows Win 7 / Win 8 / Win10 computer • Patient report storage, export, pdf options available • USB interface

Send Message
product image
Vascular Screening Products

Transcutaneous oxygen monitoring (TCOM / tcpO2) is a well-documented technique reflecting the nutritive flow in the capillaries. Today, TCOM / tcpO2 is commonly used in clinical applications such as wound-healing assessment, hyperbaric medicine, amputation-level determinations and more. Precise8001 offers the possibility to monitor the transcutaneous oxygen at the sites of interest. Features: • Fluorescence photo optical system and hence no membrane technology • No membrane and hence minimal operating cost • No pre-heating of sensor and self-automatic calibration while testing • Measurement time is less than 10 min • Automatic marking of end value • 10.1-inch large LCD touch screen Display • Displays the measurement process graphically and numerically • Integrated patient and measurement database • Oxygen partial pressure range of 0 to 2000 mmHg • Sensor temperature range 37 to 44 degree Celsius • Long enough 250cm(2.5meter) sensor cable for ease of placement • USB connection for Computer connection - Optional • Connects external memory for data transfer in txt format • Software for data transfer to computer - Optional • Standalone operation and operate with the computer if software purchased • Measurement is independent of skin pH and salt content • Weighs less than 3 kgs • Built-in rechargeable battery supports minimum 3 hours of operation • Unit works between 100Volts and 230Volts AC power supply • Truly portable

Send Message
product image
Podiatry Products

These Podiatry chairs were developed for a comfortable seated position for the client at all times. Its slender appearance makes the room or consultation area appear more spacious. In addition, the arms fold up completely, making it easy for the client to get in and out of the chair from the side. The leg supports of the chair are contoured and the height and length can be adjusted individually. Their ergonomic shape provides stable support for the lower leg and foot. PC303 - 3 function Podiatry Chair provides motorized adjustment of backrest, height and tilt using a hand remote control. PC305 - 5 function Podiatry Chair model inaddition to the PC303 model the leg rest right, left can also be adjusted individually by a motorized function.

Send Message
product image
Pain & Woundcare Products

Neurostim is a drug free, painless answer to eliminating pain and burning sense. The Neurostim works by stimulating all your nerves from your lower back down to your toes with a specific gentle waveform that your peripheral nerves naturally use to communicate with the rest of your body. The Neurostim opens your nerve paths to restore full function. All other devices temporarily treat only pain; the Neurostim permanently eliminates pain. • Relieves Your Pain and Numbness • Helps You Sleep All Night • Restores Your Balance and Mobility • Restores Feeling in Feet and Hands • Reduces or Eliminates Pain Medications The NeuroStim has proven to be highly effective in treating a number of conditions, such as: • Diabetic Nerve Pain • Peripheral Neuropathy • Diabetic Peripheral Neuropathy • Carpal Tunnel Syndrome • Chronic Inflammatory Demyelinating polyneuropathy • Muscle Spasms • Peripheral Arterial Disease • Venous Stasis • Stroke Rehabilitation • Symptoms Related to Lymph Disease • Symptoms Related to Chronic Fatigue Syndrome

Send Message
product image
Neuropathy Screening Products

One of the frequent causes of non-traumatic lower-limb amputation is Diabetes and is usually preceded by foot ulcer and infection. The reason of this ulceration is commonly a loss of protective sensation due to peripheral neuropathy, for which there is no prevention strategy. Current research promotes early detection of neuropathy so that secondary prevention measures, such as intensive foot-care education and treatment, can be used for individuals. In an effort to standardize and simplify the detection of insensate foot, the 5.07/10-gm Monofilament is recommended by the International Diabetes Federation and the World Health Organization as a device that can be used by health professionals at every level of care. A standardised filament is pressed against part of the foot. When the filament bends, its tip is exerting a pressure of 10 grams (therefore this monofilament is often referred to as the 10 gram monofilament). If the patient cannot feel the monofilament at certain specified sites on the foot, he/she has lost enough sensation to be at risk of developing a neuropathic ulcer.

Send Message

Still searching for
valuable clinical information?