Chennai
+919382206047

'model versadop dx'

Items tagged with 'model versadop dx'

product image
Neuropathy Screening Products

Failure to perceive variances in temperature in the extremities is the most decisive early symptom of distal symmetric polyneuropathy, a typical ailment accompanying diabetes mellitus (Ziegler 1988). Small-fiber Test (HCP) provides an easy-to-use and scientifically validated measure of warm, cool and heat pain thermal sensory thresholds, all clinically useful determinants in the evaluation of diabetic neuropathy. Vibration Perception Threshold (VPT) has been shown to be strongly associated with foot ulceration. VPT determination by using a Digital Biothesiometer has been used to identify peripheral sensory neuropathy and subjects at risk of the foot. Digital Biothesiometer helps us quantitate the threshold and monitor progressive changes or trends on following up testing. Sensory neuropathy increases the risk of foot ulcerations by seven-folds and peripheral arterial disease (PAD) by three folds in people with diabetes. Peripheral neuropathy is the major causal factor in the development of foot ulcerations among diabetic subjects. Early detection helps better prevention. Prevention is better than no cure. 50% of all non-traumatic amputations occur in diabetes who is a high-risk group. Our Neuropathy Analyser model Vibrotherm Dx has inbuilt both VPT and HCP in a single device. The Windows 7/8/10 supported software supplied helps to capture the VPT, COLD, HOT and Monofilament 10gm testing for storage and a patient report. FEATURES: • Full solid-state design with PC enabled • Easy Tool to quantify Neuropathy • Digital Biothesiometer VPT and Thermometry HCP combined • Digital 0 ~ 50 Volts Vibration output • 1 ~ 50o C temperature output range • 1o C rate of change per second • Remote keypad helps easy operation • Single probe delivers both Hot & Cold temperatures • Automatic interpretation based on set reference values • Early detection of Small Fiber Neuropathy • Software supports Windows Win 7 / Win 8 / Win10 computer • Patient report storage, export, pdf options available • USB interface

Send Message
product image
Diabetic Foot Evaluation Lab

Automated diabetic foot evaluation lab model Diabetik Autolab is capable of screening (1) Vascular Insufficiencies using Ankle Brachial Index, Toe Brachial Index, Velocity waveform analysis, (2) Diabetic neuropathy using loss of vibration perception threshold (VPT)-Biothesiometry and loss of protective touch sense-Monofilament 10gm, (3) plantar pressure screening using advance electronic sensor platform by checking static(weight bearing), dynamic(walking) and postural imbalance, (4) Non-contact measurement of temperature in the foot for early assessment of inflammation in the foot. A master report is generated with the patients clinical information, medical information and the measured data with interpretation. Device is supplied in a trolley and a branded i3 based laptop computer and an EPSON ink tank printer. Sales and service team across India to train the user periodically. ISO13485:2016 certified company.

Send Message
product image
Diabetic Foot Evaluation Lab

Our All-in-one Complete Diabetic Foot Lab model DIABETIK MINILAB is our one of the best products that can measure and document all the important parameters such as the Ankle Brachial Index(ABI), Toe Brachial Index(TBI), Doppler Waveform, Monofilament 10gm, Biothesiometry, Foot Pressure and Foot Temperature. In addition to the above reports, a master report is created by the software will capture the medical history with symptoms of the patient, dermatological exam, musculoskeletal exam, vascular and footwear exams along with the recorded test results and their interpretations. A colorful 6 pages report is generated by the software. The Diabetik Minilab is supplied with all the accessories and a sturdy trolley. An all-in-one scanner/copier/printer of a particular specification is supplied with the device. A Windows 7/8/10 operated laptop is to be arranged by the buyer. Vascular Screening: Whenever one suspects Peripheral Arterial Disease (PAD), the clinician must perform a few non-invasive vascular testing methods that are commercially available and widely implemented. Features: • Unidirectional 8MHz probe • Photo-plethysmograph PPG Toe sensor • BP cuffs for ABI/TBI • Ankle Brachial Index (ABI) • Toe Brachial Index (TBI) • Doppler Velocity Waveform • Venous Examination (No documentation) • Carotid, Penile examination (No documentation) Neuropathy Screening: Diabetes can result in long-term health complications, with one of the most common being microvascular damage that leads to diabetic neuropathy (DN), which affects multiple body systems and increases amputation risk. A typical form of DN is diabetic peripheral neuropathy (DPN), which is known to be a primary cause of balance issues, and sensation loss in the feet, and a major contributor to nontraumatic lower-limb amputations. Loss of sensation in the foot can be diagnosed with a 10gm Monofilament and a Biothesiometry. Semmes‐Weinstein monofilament test (SWMT): The SWMT is a common screening tool for assessing the sensory function and the loss of pressure sensation (light touch perception). A 10-gm monofilament test (also referred to as the 5.07 monofilament) is the most common in practice. 25 Nos of such monofilament in a box are supplied with the device. The filament is applied to at least six sites on the foot until it buckles, which occurs at 10 g of linear pressure when the patient is asked to detect its presence. If it is not detected on at least four out of six sites, then the protective sensation is considered to be lost. Biothesiometry: Vibration perception threshold (VPT) has been shown to be strongly associated with foot ulceration. VPT determination by using a Digital Biothesiometer has been used to identify peripheral sensory neuropathy and subjects at risk of the foot. Digital Biothesiometer helps us quantitate the threshold and monitor progressive changes or trends on following up testing. Sensory neuropathy increases the risk of foot ulcerations by seven-fold and peripheral arterial disease (PAD) by three folds in people with diabetes. Peripheral neuropathy is the major causal factor in the development of foot ulcerations among diabetic subjects. Early detection of vibration perception threshold (VPT) helps better prevention. Prevention is better than no cure. 50% of all non-traumatic amputations occur in diabetes which is a high-risk group. . Features: • First Company to introduce Digital Biothesiometry in India - 2003 • Digital 0 to 50 Volts indicator • Vibrator with Mute/Check & Record key • Full solid-state design Plantar Pressure measurement: Understanding foot biomechanics is an important component in the evaluation of diabetic foot. The abnormal plantar pressure distribution plays a key role in the formation of plantar calluses and diabetic foot ulcers. Abnormal value of foot pressure, as well as neuropathy, could play an important role in the formation of plantar ulcers independently. Current international guidelines advocate achieving at least a 30 % reduction in maximum plantar pressure to reduce the risk of foot ulcers in people with diabetes. Features: • Foot Imprinter Harris Mat FM1111 • Licensed software to scan and image process FM1111 foot image. • Report to include the footwear measurements. • Multi-color picture image indicates the pressure mapping. IR Foot Temperature measurement: Monitoring of skin temperatures at the foot, along with subsequent offloading can dramatically reduce the occurrence of ulcerations. The defined threshold reported in numerous studies is an asymmetrical difference of 4ºF (2.2°C) between the sites. Because most patients at risk for ulceration are also at risk for Charcot, monitoring foot temperature would be an effective tool. Features: • Simple one-handed operation • Laser targeting • oC / oF select switch, Accuracy +/- 2% • Early marker for Charcot foot • Can reduce the risk of ulceration.

Send Message
product image
Neuropathy Screening Products

VibraTip a wipe-clean, pocket-sized and disposable device for testing vibration sense. Vibration sense is typically one of the first sensory modalities to be impaired as peripheral neuropathy develops. Graduated tuning forks (e.g. Reidel-Seiffer) and calibrated electronic devices (e.g. Neurothesiometer, Bio-Thesiometer Vibrometer) are recommended to quantify the integrity of vibration sensation. VibraTip is a wipe-clean, disposable, key fob-sized device that provides a constant and reproducible source of vibration. The spherical head facilitates application from any angle and its pocket size means that it is easy to carry and therefore likely to be available at the point of use.

Send Message
product image
Plantar Pressure Measurement Systems

The Podiascan system provides podiatrists and bio-mechanists with an economical and efficient method to measure static and dynamic plantar foot pressure distribution. The Podiascan system produces instantaneous and permanent high resolution image of the pressure distribution across the planter surface. We sell this product only in India. The Harris Mat paper output is scanned and the resultant grey scale image is converted into colour scale. Features : • System consists of Harris Mat, Special Scanner Copier and Printer, Image Analysis Software and Patient Reporting Software. • Economical method to measure Static and Dynamic Plantar foot pressure. • Qualitative multi-colour output makes the pressure reading easier. Used to Identify : • Areas of potential ulceration • Pre and Post surgical evaluation • Degree of pronation or supination • Weight bearing after surgery

Send Message

Still searching for
model versadop dx?