Diabetic Neuropathy Products

The vibration Perception Threshold (VPT) has been shown to be strongly associated with foot ulceration. VPT determination by using a Digital Biothesiometer has been used to identify peripheral sensory neuropathy and subjects at risk of foot. Digital Biothesiometer helps us quantitate the threshold and monitor progressive changes or trends on following up testing. Sensory neuropathy increases the risk of foot ulcerations by seven-fold and peripheral arterial disease (PAD) by three folds in people with diabetes. Peripheral neuropathy is the major causal factor in the development of foot ulcerations among diabetic subjects. Early detection helps better prevention. Prevention is better than no cure. 50% of all non-traumatic amputations occur in diabetes which is a high-risk group. Our portable vibration sense Biothesiometer VIBROMETER is compatible with Windows 7/8/10/11 operated computers. Android support in available. Features: • Full solid-state design • Electronic Tuning Fork • Easy tool to quantify neuropathy • Digital 0 to 50 Volts indicator • Vibration Check/Mute key on the probe • Data record key on the probe • Computer Connectivity through USB and Bluetooth • Automatic Port Setting • Automatic Interpretation of result • Interpretation rule can be edited • Data Export/Retrieve available • Products tested by an International accredited test lab • Weighs less than 3 Kg • Largest exported product from India • 230V, AC, 50Hz Mains operation(110V, AC, 60Hz option)

Send Message
product image
Diabetic Neuropathy Products

The vibration Perception Threshold (VPT) has been shown to be strongly associated with foot ulceration. VPT determination by using a Digital Biothesiometer has been used to identify peripheral sensory neuropathy and subjects at risk of foot. Digital Biothesiometer helps us quantitate the threshold and monitor progressive changes or trends on following up testing. Sensory neuropathy increases the risk of foot ulcerations by seven-fold and peripheral arterial disease (PAD) by three folds in people with diabetes. Peripheral neuropathy is the major causal factor in the development of foot ulcerations among diabetic subjects. Early detection helps better prevention. Prevention is better than no cure. 50% of all non-traumatic amputations occur in diabetes which is a high-risk group. Our portable vibration sense Biothesiometer is compatible with Windows 7/8/10/11 operated computers. Features: • Full solid-state design • Electronic Tuning Fork • Easy tool to quantify neuropathy • Digital 0 to 50 Volts indicator • Vibration Check/Mute key on the probe • Data record key on the probe • Computer Connectivity through USB • Automatic Port Setting • Automatic Interpretation of result • Interpretation rule can be edited • Data Export/Retrieve available • Products tested by an International accredited test lab • Weighs less than 3 Kg • Largest exported product from India • 230V, AC, 50Hz Mains operation(110V, AC, 60Hz option)

Send Message
product image
Podiatry Products

Features: • Motorised drill. • Variable speed setting. • Maximum speed of drill is 35000 RPM • Maximum power of the unit - 65 Watts • Forward and Reverse rotation is possible • Remote foot switch is provided • Foot switch have speed adjustment as pressed • Micromotor handle have lock and release chuck • Autoclavable diamond burr tools for repairing fissures, corn and callouses • Autoclavable diamond burr tools for trimming nails • Atleast 8 different diamond burr bit tools are provided with the unit • Unit operational with 230V, AC, 50Hz • Video demo CD is supplied with unit • We are an ISO13485:2016 certified Company.

Send Message
product image
Plantar Pressure Measurement Systems

Deformity due to the diabetic foot causes repetitive and excessive pressure to certain areas of the foot, which may result in ulcers and pains. Therefore, it is necessary to measure the pressure of the sole for the prevention and management of diabetic foot lesions. Early identification of feet 'at risk' for ulceration is important in preventing plantar lesions in diabetic patients with insensitive feet. Plantar pressures are higher in diabetic neuropathic patients than non-diabetic and non-neuropathic Counterparts. As high plantar pressure is a proven risk factor for foot ulceration, effective screening for high plantar pressures in diabetic patients could have a major influence on the incidence of diabetic foot ulceration. High plantar foot pressure has been identified as a significant risk factor for ulcerations. A large number of studies have suggested that plantar pressures are high in people with diabetic peripheral neuropathy (DPN) and in people with a history of diabetic foot ulcers. Measurement of these foot pressures is possible utilizing a variety of modalities. Several computerized systems can provide quantitative measurement of plantar foot pressure. These measurements are important in identifying areas of the foot at risk for ulceration and possibly in the evaluation of orthotic adjustments. In order to identify high-risk patients in a clinical setting, a simple system for screening is needed which is easy to use, reliable and gives results that are easy to interpret and can be immediately available to both the patient and staff. Our Foot Imprinter Harris Mat FM1111 has been developed as a simple, inexpensive and practical foot pressure measurement device intended for routine clinical use. It is a semiquantitative footprint mat that quantifies plantar pressure by visual comparison between the greyness of the footprint. Features: • Measures and display patient weight disbursement in greyscale • Detects the area of the greatest concern for ulceration • Useful to identify Charcot arthropathy • Arch of the patient can be detected • More the darker color represent the high pressure • Excellent tool for motivating the patient to upgrade to a good footwear • Kit includes FI1111 mat, rubber roller, ink pad, Ink and prescription pad

Send Message
product image
Neuropathy Screening Products

Failure to perceive variances in temperature in the extremities is the most decisive early symptom of distal symmetric polyneuropathy, a typical ailment accompanying diabetes mellitus (Ziegler 1988). Small-fiber Test (HCP) provides an easy-to-use and scientifically validated measure of warm, cool and heat pain thermal sensory thresholds, all clinically useful determinants in the evaluation of diabetic neuropathy. Vibration Perception Threshold (VPT) has been shown to be strongly associated with foot ulceration. VPT determination by using a Digital Biothesiometer has been used to identify peripheral sensory neuropathy and subjects at risk of the foot. Digital Biothesiometer helps us quantitate the threshold and monitor progressive changes or trends on following up testing. Sensory neuropathy increases the risk of foot ulcerations by seven-folds and peripheral arterial disease (PAD) by three folds in people with diabetes. Peripheral neuropathy is the major causal factor in the development of foot ulcerations among diabetic subjects. Early detection helps better prevention. Prevention is better than no cure. 50% of all non-traumatic amputations occur in diabetes who is a high-risk group. Our Neuropathy Analyser model Vibrotherm Dx has inbuilt both VPT and HCP in a single device. The Windows 7/8/10 supported software supplied helps to capture the VPT, COLD, HOT and Monofilament 10gm testing for storage and a patient report. FEATURES: • Full solid-state design with PC enabled • Easy Tool to quantify Neuropathy • Digital Biothesiometer VPT and Thermometry HCP combined • Digital 0 ~ 50 Volts Vibration output • 1 ~ 50o C temperature output range • 1o C rate of change per second • Remote keypad helps easy operation • Single probe delivers both Hot & Cold temperatures • Automatic interpretation based on set reference values • Early detection of Small Fiber Neuropathy • Software supports Windows Win 7 / Win 8 / Win10 computer • Patient report storage, export, pdf options available • USB interface

Send Message
product image
Vascular Screening Products

Transcutaneous oxygen monitoring (TCOM / tcpO2) is a well-documented technique reflecting the nutritive flow in the capillaries. Today, TCOM / tcpO2 is commonly used in clinical applications such as wound-healing assessment, hyperbaric medicine, amputation-level determinations and more. Precise8001 offers the possibility to monitor the transcutaneous oxygen at the sites of interest. Features: • Fluorescence photo optical system and hence no membrane technology • No membrane and hence minimal operating cost • No pre-heating of sensor and self-automatic calibration while testing • Measurement time is less than 10 min • Automatic marking of end value • 10.1-inch large LCD touch screen Display • Displays the measurement process graphically and numerically • Integrated patient and measurement database • Oxygen partial pressure range of 0 to 2000 mmHg • Sensor temperature range 37 to 44 degree Celsius • Long enough 250cm(2.5meter) sensor cable for ease of placement • USB connection for Computer connection - Optional • Connects external memory for data transfer in txt format • Software for data transfer to computer - Optional • Standalone operation and operate with the computer if software purchased • Measurement is independent of skin pH and salt content • Weighs less than 3 kgs • Built-in rechargeable battery supports minimum 3 hours of operation • Unit works between 100Volts and 230Volts AC power supply • Truly portable

Send Message
product image
Neuropathy Screening Products

VibraTip a wipe-clean, pocket-sized and disposable device for testing vibration sense. Vibration sense is typically one of the first sensory modalities to be impaired as peripheral neuropathy develops. Graduated tuning forks (e.g. Reidel-Seiffer) and calibrated electronic devices (e.g. Neurothesiometer, Bio-Thesiometer Vibrometer) are recommended to quantify the integrity of vibration sensation. VibraTip is a wipe-clean, disposable, key fob-sized device that provides a constant and reproducible source of vibration. The spherical head facilitates application from any angle and its pocket size means that it is easy to carry and therefore likely to be available at the point of use.

Send Message
product image
Neuropathy Screening Products

This basic neuropathy Assessment kit consists of one Tiptherm, one VibraTip and 25 Nos. 10gm Monofilaments to check the loss of temperature, vibration and touch sensitivity. Early diagnosis of distal symmetric polyneuropathy by testing temperature sensitivity, can prevent complications of diabetic foot. Precious time is gained if examinations are geared towards detecting this symptom. Regular testing of temperature sensitivity should therefore be a compulsory part of basic diabetes treatment. Failure to perceive variances in temperature in the extremities is the most decisive early symptom of distal symmetric polyneuropathy, a typical ailment accompanying diabetes mellitus (Ziegler 1988). TIP THERM® is ideal for testing temperature sensitivity. It is not dependent on external power sources, is practically indestructible, easy to handle and small and light enough to fit in any jacket or overall pocket. VibraTipTM: a wipe-clean, pocket-sized and disposable device for testing vibration sense. The advantages include ease and speed of the test with little required training, less user variability compared with the calibrated tuning-fork test, small size, and easy cleaning.

Send Message
product image
Plantar Pressure Measurement Systems

The Podiascan system provides podiatrists and bio-mechanists with an economical and efficient method to measure static and dynamic plantar foot pressure distribution. The Podiascan system produces instantaneous and permanent high resolution image of the pressure distribution across the planter surface. We sell this product only in India. The Harris Mat paper output is scanned and the resultant grey scale image is converted into colour scale. Features : • System consists of Harris Mat, Special Scanner Copier and Printer, Image Analysis Software and Patient Reporting Software. • Economical method to measure Static and Dynamic Plantar foot pressure. • Qualitative multi-colour output makes the pressure reading easier. Used to Identify : • Areas of potential ulceration • Pre and Post surgical evaluation • Degree of pronation or supination • Weight bearing after surgery