Chennai
+919382206047

Vascular Doppler for ABI - VERSADOP Dx Diabetik F...

update image
Vascular Doppler for ABI - VERSADOP Dx Diabetik Foot Care India Pvt Ltd is a pioneer in the manufacturing and distribution of medical devices for the management of diabetic foot and its complications. Our Product Range: Handheld Vascular Doppler, Automatic Vascular Doppler Recorder, Digital Biothesiometer, Foot Scanner, Pedography, Plantar Scan Systems, tcpO2, Monofilament 10gm, Neuropathy Therapy Stimulator, IR Light Theraphy, Podiatry chair and instruments are our major products. The Ankle Brachial Index (ABI) is a measure of the severity of atherosclerosis in the legs but is also an independent indicator of the risk of subsequent atherothrombotic events elsewhere in the vascular system. The ABI may be used as a risk marker both in the general population free of clinical CVD and in patients with established CVD. Continuous wave Doppler ultrasound is considered a reliable tool and was validated and accepted into routine medical practice. The literature recognises the importance of assessment in the management of a patient with chronic lower limb ulceration. The evidence from the medical literature indicates that a "normal" ABI is 0.91 or greater, a ratio below this indicating arterial disease. Patients with DM may have calcified and hardened lower extremity arterial walls that cannot be readily compressed and occluded with blood pressure cuffs. This produces falsely elevated ankle pressure readings that are often in the “normal ABI range” (0.9 to 1.4) or sometimes in the non-physiological range of above 1.4. However, Calcified leg arteries in Diabetes Mellitus or dialysis patients may yield falsely elevated ABI results. FEATURES: • Doppler (C.W) with 8MHz Transducer • Software to measure ABI • ABI measurement as per TASC II guidelines • Penile flow study • Arterial and venous examinations made simple • Software for complete arterial vascular profile • Computer connectivity through USB enabled • Software for data transfer, storage and patient report • Software supports Windows Win 7/ Win 8/ Win10 operated computer • Standards matching International standards For a free demo, please do contact us.
 2020-07-10T09:41:08

Related Posts

update image

Use and Role of Podiatry Instrument Kits:

2025-09-16T18:30:21 , update date

 2025-09-16T18:30:21
update image

Use and Role of Electric Pedicure Files in Diabetic Foot Management:

2025-09-13T18:30:01 , update date

 2025-09-13T18:30:01
update image

Use and Role of a Digital Biothesiometer in Diabetic Neuropathy Screening: VIBROMETER

2025-09-10T18:30:01 , update date

 2025-09-10T18:30:01
update image

Understanding Cardiac Autonomic Neuropathy System Analyser:

2025-09-07T18:30:11 , update date

 2025-09-07T18:30:11