Chennai
+919382206047

'stable support'

Items tagged with 'stable support'

product image
Neuropathy Screening Products

VibraTip a wipe-clean, pocket-sized and disposable device for testing vibration sense. Vibration sense is typically one of the first sensory modalities to be impaired as peripheral neuropathy develops. Graduated tuning forks (e.g. Reidel-Seiffer) and calibrated electronic devices (e.g. Neurothesiometer, Bio-Thesiometer Vibrometer) are recommended to quantify the integrity of vibration sensation. VibraTip is a wipe-clean, disposable, key fob-sized device that provides a constant and reproducible source of vibration. The spherical head facilitates application from any angle and its pocket size means that it is easy to carry and therefore likely to be available at the point of use.

Send Message
product image
Diabetic Neuropathy Products

The vibration Perception Threshold (VPT) has been shown to be strongly associated with foot ulceration. VPT determination by using a Digital Biothesiometer has been used to identify peripheral sensory neuropathy and subjects at risk of foot. Digital Biothesiometer helps us quantitate the threshold and monitor progressive changes or trends on following up testing. Sensory neuropathy increases the risk of foot ulcerations by seven-fold and peripheral arterial disease (PAD) by three folds in people with diabetes. Peripheral neuropathy is the major causal factor in the development of foot ulcerations among diabetic subjects. Early detection helps better prevention. Prevention is better than no cure. 50% of all non-traumatic amputations occur in diabetes which is a high-risk group. Our portable vibration sense Biothesiometer VIBROMETER is compatible with Windows 7/8/10/11 operated computers. Android support in available. Features: • Full solid-state design • Electronic Tuning Fork • Easy tool to quantify neuropathy • Digital 0 to 50 Volts indicator • Vibration Check/Mute key on the probe • Data record key on the probe • Computer Connectivity through USB and Bluetooth • Automatic Port Setting • Automatic Interpretation of result • Interpretation rule can be edited • Data Export/Retrieve available • Products tested by an International accredited test lab • Weighs less than 3 Kg • Largest exported product from India • 230V, AC, 50Hz Mains operation(110V, AC, 60Hz option)

Send Message
product image
Neuropathy Screening Products

Failure to perceive variances in temperature in the extremities is the most decisive early symptom of distal symmetric polyneuropathy, a typical ailment accompanying diabetes mellitus (Ziegler 1988). Small-fiber Test (HCP) provides an easy-to-use and scientifically validated measure of warm, cool and heat pain thermal sensory thresholds, all clinically useful determinants in the evaluation of diabetic neuropathy. Vibration Perception Threshold (VPT) has been shown to be strongly associated with foot ulceration. VPT determination by using a Digital Biothesiometer has been used to identify peripheral sensory neuropathy and subjects at risk of the foot. Digital Biothesiometer helps us quantitate the threshold and monitor progressive changes or trends on following up testing. Sensory neuropathy increases the risk of foot ulcerations by seven-folds and peripheral arterial disease (PAD) by three folds in people with diabetes. Peripheral neuropathy is the major causal factor in the development of foot ulcerations among diabetic subjects. Early detection helps better prevention. Prevention is better than no cure. 50% of all non-traumatic amputations occur in diabetes who is a high-risk group. Our Neuropathy Analyser model Vibrotherm Dx has inbuilt both VPT and HCP in a single device. The Windows 7/8/10 supported software supplied helps to capture the VPT, COLD, HOT and Monofilament 10gm testing for storage and a patient report. FEATURES: • Full solid-state design with PC enabled • Easy Tool to quantify Neuropathy • Digital Biothesiometer VPT and Thermometry HCP combined • Digital 0 ~ 50 Volts Vibration output • 1 ~ 50o C temperature output range • 1o C rate of change per second • Remote keypad helps easy operation • Single probe delivers both Hot & Cold temperatures • Automatic interpretation based on set reference values • Early detection of Small Fiber Neuropathy • Software supports Windows Win 7 / Win 8 / Win10 computer • Patient report storage, export, pdf options available • USB interface

Send Message
product image
Vascular Screening Products

Transcutaneous oxygen monitoring (TCOM / tcpO2) is a well-documented technique reflecting the nutritive flow in the capillaries. Today, TCOM / tcpO2 is commonly used in clinical applications such as wound-healing assessment, hyperbaric medicine, amputation-level determinations and more. Precise8001 offers the possibility to monitor the transcutaneous oxygen at the sites of interest. Features: • Fluorescence photo optical system and hence no membrane technology • No membrane and hence minimal operating cost • No pre-heating of sensor and self-automatic calibration while testing • Measurement time is less than 10 min • Automatic marking of end value • 10.1-inch large LCD touch screen Display • Displays the measurement process graphically and numerically • Integrated patient and measurement database • Oxygen partial pressure range of 0 to 2000 mmHg • Sensor temperature range 37 to 44 degree Celsius • Long enough 250cm(2.5meter) sensor cable for ease of placement • USB connection for Computer connection - Optional • Connects external memory for data transfer in txt format • Software for data transfer to computer - Optional • Standalone operation and operate with the computer if software purchased • Measurement is independent of skin pH and salt content • Weighs less than 3 kgs • Built-in rechargeable battery supports minimum 3 hours of operation • Unit works between 100Volts and 230Volts AC power supply • Truly portable

Send Message
product image
Vascular Screening Products

Vasochek+ is a complete non-invasive unidirectional vascular doppler recorder designed to measure the ABI, TBI and the velocity waveform with a connection to a windows 7/8/10 operated computer for storage of data and patient report generation. Interpretation as per TASC II guidelines. FEATURES: • Ankle Brachial Index and Toe Brachial Index • Doppler (C.W) with 8MHz Transducer • Photo-Plethysmography (PPG) Toe sensor • Semi-automated system • Software for ABI/TBI with Waveform • Computer connectivity enabled • Software for data transfer, storage and patient report • Software supports Windows 7/8/10 • Standards matching International standards

Send Message
product image
Podiatry Products

Inflammation is one of the earliest signs of tissue injury and ulceration. However, the clinical signs of inflammation are usually too subtle to be detected by patients or even by trained health care providers. We hypothesized that skin temperatures could be used as a surrogate measure of injury and localized inflammation. Skin temperature measurements can be easily performed and assessed by the lay public and have been used as a diagnostic tool for diabetic foot ulcerations The aim of this product is to help high-risk individuals identify areas on their feet that are inflamed and prone to ulceration before a wound develops. The patients to record foot temperatures in the great toe, the first, third, and fifth metatarsal head region, the midfoot, and the heel. If skin temperatures were elevated by >40F (2.20C) compared with the corresponding site on the opposite foot for two consecutive days, subjects were instructed to contact the hospital and decrease their activity until temperatures normalized. Software is supplied for storing the data in computer free of cost along with the instrument. Features : • Early marker for identifying foot ulcer • Simple One handed operation • 3.1/2 digit LCD with back light • Accuracy +/- 2 • Early marker for Charcot foot • Laser targeting • oC / oF select switch

Send Message

Still searching for
stable support?