Chennai
+919382206047

'small battery'

Items tagged with 'small battery'

product image
Vascular Screening Products

The handheld Unidirectional ultrasound vascular Doppler is an instrument that detects blood flow using the principles of the Doppler effect. It can be a very useful tool in assessing how good the blood flow is to the foot or hand. It is a painless test and very similar to taking blood pressure using a stethoscope. It is particularly useful for the assessment of arterial disease but can also be used for venous problems. These vascular Doppler are used for identifying the arterial and venous flow patency. Ankle Brachial Index (ABI) is a simple procedure to detect obstruction in the blood flow. The LifeDop 150R features a non-display, handheld Doppler with superior sound quality, extended battery life, enhanced probe sensitivity, interchangeable probes, and a one-year full warranty. It includes a battery recharging system, so you don’t have to worry about overcharging or draining of the batteries. Features: • Interchangeable Doppler Probes • Unidirectional Doppler • 8MHz Vascular Probe is Standard • Continuous Wave Doppler • 4, 5 and 8 MHz Vascular probes • Rechargeable battery operation • Charger supplied free

Send Message
product image
Diabetic Neuropathy Products

Peripheral neuropathy is the prime cause of diabetic foot ulceration. Ulceration, in turn, is the key factor that may precipitate a cascade of events leading to lower-extremity amputation. Checking the loss of Thermal Sense, Vibration sense and protective Touch Sense will help the management of diabetic neuropathy and its effect on the foot. Three important simple devices are packaged in the Neuropathy Assessment Kit (NA03) for the effective management of diabetic neuropathy. The kit contains a Tiptherm, a Vibratip and Monofilament 10gm(25 Nos). TIP THERM® is a simple device for the early diagnosis of symmetrical polyneuropathy by measuring the loss of temperature sensitivity of the skin. TIP THERM® was developed to give the clinician and patient a convenient and easy-to-use method of testing. This device is recommended to use, at a room temperature of 23° C. Failure to perceive variances in temperature in the extremities is the most decisive early symptom of distal symmetric polyneuropathy, a typical ailment accompanying diabetes mellitus (Ziegler 1988). Portable Vibration sense device VIBRATIPTM is a device resembling a small key fob that provides a near-silent vibration of consistent amplitude at a frequency similar to that of a calibrated tuning fork. It is intended for use when testing a person’s vibration perception during routine checks for diabetic peripheral neuropathy (DPN) in people who have type 1 or type 2 diabetes. It is a disposable device works for about 250 patients, and vibrates at 125 Hz with an intensity equivalent to that of a Biothesiometer at 25 Volts. When the patient does not feel the vibration is classified as a high-risk category. MF10GM: Monofilaments 10gm is an effective, convenient, easy to use, relatively inexpensive way of testing for loss of protective touch sense in the feet. It is designed for single-patient use and can be used till 100 bends or filament damage.

Send Message
product image
Diabetic Neuropathy Products

Monofilaments MF10GM contain a small strand of filament attached to a visiting card-like handle. When placed upon the skin perpendicularly and applied an amount of pressure before the filament bends or buckles. The point at which the filament bends or buckles is rated in grams of force. 10gm Monofilament is widely accepted by the medical community and recommended by WHO and IDF for evaluating the loss of protective touch sense. The MF10GM Monofilament is intended to be used to determine whether a person with diabetes has the presence of an adequate level of protective sensation in their feet as indicated by having enough tactile sensitivity to perceive 10 grams of force against the skin of their feet. The monofilament is tested on multiple points on the foot of the person to be tested and they should feel the sense in the majority of the test points. If they don’t feel the sense in multiple spots, then it is indicated that they would have lost the protective touch sense. It should be used on adult Diabetic patients on a periodic basis to evaluate changes in sensory perception in the feet due to Diabetic peripheral sensory neuropathy. This device is not a complete replacement for routine sensory evaluation by a health care provider. They are available in a box of 25pcs and cost Rs. 650 inclusive of GST and Courier.

Send Message
product image
General

An orchidometer is a medical instrument used to measure the volume of the testicles. Normal volume is 15 to 25 ml; the average is 18 cm³ per testis (range 12 cm³ to 30 cm³). The discrepancy of testicular size with other parameters of maturation can be an important clue to various diseases. Small testes can indicate either primary or secondary hypogonadism. Testicular size can help distinguish between different types of precocious puberty. Since testicular growth is typically the first physical sign of true puberty, one of the most common uses is as confirmation that puberty is beginning in a boy with delay. Large testes (macroorchidism) can be a clue to one of the most common causes of inherited generalized learning disability, fragile X syndrome..

Send Message
product image
Neuropathy Screening Products

Failure to perceive variances in temperature in the extremities is the most decisive early symptom of distal symmetric polyneuropathy, a typical ailment accompanying diabetes mellitus (Ziegler 1988). Small-fiber Test (HCP) provides an easy-to-use and scientifically validated measure of warm, cool and heat pain thermal sensory thresholds, all clinically useful determinants in the evaluation of diabetic neuropathy. Vibration Perception Threshold (VPT) has been shown to be strongly associated with foot ulceration. VPT determination by using a Digital Biothesiometer has been used to identify peripheral sensory neuropathy and subjects at risk of the foot. Digital Biothesiometer helps us quantitate the threshold and monitor progressive changes or trends on following up testing. Sensory neuropathy increases the risk of foot ulcerations by seven-folds and peripheral arterial disease (PAD) by three folds in people with diabetes. Peripheral neuropathy is the major causal factor in the development of foot ulcerations among diabetic subjects. Early detection helps better prevention. Prevention is better than no cure. 50% of all non-traumatic amputations occur in diabetes who is a high-risk group. Our Neuropathy Analyser model Vibrotherm Dx has inbuilt both VPT and HCP in a single device. The Windows 7/8/10 supported software supplied helps to capture the VPT, COLD, HOT and Monofilament 10gm testing for storage and a patient report. FEATURES: • Full solid-state design with PC enabled • Easy Tool to quantify Neuropathy • Digital Biothesiometer VPT and Thermometry HCP combined • Digital 0 ~ 50 Volts Vibration output • 1 ~ 50o C temperature output range • 1o C rate of change per second • Remote keypad helps easy operation • Single probe delivers both Hot & Cold temperatures • Automatic interpretation based on set reference values • Early detection of Small Fiber Neuropathy • Software supports Windows Win 7 / Win 8 / Win10 computer • Patient report storage, export, pdf options available • USB interface

Send Message
product image
Vascular Screening Products

Transcutaneous oxygen monitoring (TCOM / tcpO2) is a well-documented technique reflecting the nutritive flow in the capillaries. Today, TCOM / tcpO2 is commonly used in clinical applications such as wound-healing assessment, hyperbaric medicine, amputation-level determinations and more. Precise8001 offers the possibility to monitor the transcutaneous oxygen at the sites of interest. Features: • Fluorescence photo optical system and hence no membrane technology • No membrane and hence minimal operating cost • No pre-heating of sensor and self-automatic calibration while testing • Measurement time is less than 10 min • Automatic marking of end value • 10.1-inch large LCD touch screen Display • Displays the measurement process graphically and numerically • Integrated patient and measurement database • Oxygen partial pressure range of 0 to 2000 mmHg • Sensor temperature range 37 to 44 degree Celsius • Long enough 250cm(2.5meter) sensor cable for ease of placement • USB connection for Computer connection - Optional • Connects external memory for data transfer in txt format • Software for data transfer to computer - Optional • Standalone operation and operate with the computer if software purchased • Measurement is independent of skin pH and salt content • Weighs less than 3 kgs • Built-in rechargeable battery supports minimum 3 hours of operation • Unit works between 100Volts and 230Volts AC power supply • Truly portable

Send Message
product image
Vascular Screening Products

DFCI offers a full-featured automated ABI/TBI Vascular System for the diagnosis of PAD. ABI/TBI/PVR/Segmental Doppler/Upper extremity/Carotid Doppler/Penile Doppler/Venous Doppler are the different modalities possible with this model. The system includes 6 pressure cuffs, a graphic waveform LCD display, automatic cuff inflation and deflation along with automatic indices calculation. PC software and USB connectivity are included for storage and performing the standard protocols. Features:- • Automatic ABI, TBI, PVR and segmental measurement • Automatic cuff inflation and deflation system • Guided step by step protocol • Large graphic LCD display • Uni-Directional 8 MHz Doppler Probe • PVR waveform • Photoplethysmography PPG Toe Sensor for TBI • Special Toe cuff is supplied • Separate mode for complete vascular profile study • Penile flow study • Gets connected on to any computer • Standards matching the International specification • Software for patient report generation & storage.

Send Message
product image
Neuropathy Screening Products

One of the frequent causes of non-traumatic lower-limb amputation is Diabetes and is usually preceded by foot ulcer and infection. The reason of this ulceration is commonly a loss of protective sensation due to peripheral neuropathy, for which there is no prevention strategy. Current research promotes early detection of neuropathy so that secondary prevention measures, such as intensive foot-care education and treatment, can be used for individuals. In an effort to standardize and simplify the detection of insensate foot, the 5.07/10-gm Monofilament is recommended by the International Diabetes Federation and the World Health Organization as a device that can be used by health professionals at every level of care. A standardised filament is pressed against part of the foot. When the filament bends, its tip is exerting a pressure of 10 grams (therefore this monofilament is often referred to as the 10 gram monofilament). If the patient cannot feel the monofilament at certain specified sites on the foot, he/she has lost enough sensation to be at risk of developing a neuropathic ulcer.

Send Message

Still searching for
small battery?