Chennai
+919382206047

'enough sanitiser'

Items tagged with 'enough sanitiser'

product image
Diabetic Neuropathy Products

Monofilaments MF10GM contain a small strand of filament attached to a visiting card-like handle. When placed upon the skin perpendicularly and applied an amount of pressure before the filament bends or buckles. The point at which the filament bends or buckles is rated in grams of force. 10gm Monofilament is widely accepted by the medical community and recommended by WHO and IDF for evaluating the loss of protective touch sense. The MF10GM Monofilament is intended to be used to determine whether a person with diabetes has the presence of an adequate level of protective sensation in their feet as indicated by having enough tactile sensitivity to perceive 10 grams of force against the skin of their feet. The monofilament is tested on multiple points on the foot of the person to be tested and they should feel the sense in the majority of the test points. If they don’t feel the sense in multiple spots, then it is indicated that they would have lost the protective touch sense. It should be used on adult Diabetic patients on a periodic basis to evaluate changes in sensory perception in the feet due to Diabetic peripheral sensory neuropathy. This device is not a complete replacement for routine sensory evaluation by a health care provider. They are available in a box of 25pcs and cost Rs. 650 inclusive of GST and Courier.

Send Message
product image
Vascular Screening Products

Transcutaneous oxygen monitoring (TCOM / tcpO2) is a well-documented technique reflecting the nutritive flow in the capillaries. Today, TCOM / tcpO2 is commonly used in clinical applications such as wound-healing assessment, hyperbaric medicine, amputation-level determinations and more. Precise8001 offers the possibility to monitor the transcutaneous oxygen at the sites of interest. Features: • Fluorescence photo optical system and hence no membrane technology • No membrane and hence minimal operating cost • No pre-heating of sensor and self-automatic calibration while testing • Measurement time is less than 10 min • Automatic marking of end value • 10.1-inch large LCD touch screen Display • Displays the measurement process graphically and numerically • Integrated patient and measurement database • Oxygen partial pressure range of 0 to 2000 mmHg • Sensor temperature range 37 to 44 degree Celsius • Long enough 250cm(2.5meter) sensor cable for ease of placement • USB connection for Computer connection - Optional • Connects external memory for data transfer in txt format • Software for data transfer to computer - Optional • Standalone operation and operate with the computer if software purchased • Measurement is independent of skin pH and salt content • Weighs less than 3 kgs • Built-in rechargeable battery supports minimum 3 hours of operation • Unit works between 100Volts and 230Volts AC power supply • Truly portable

Send Message
product image
Vascular Screening Products

DFCI offers a full-featured automated ABI/TBI Vascular System for the diagnosis of PAD. ABI/TBI/PVR/Segmental Doppler/Upper extremity/Carotid Doppler/Penile Doppler/Venous Doppler are the different modalities possible with this model. The system includes 6 pressure cuffs, a graphic waveform LCD display, automatic cuff inflation and deflation along with automatic indices calculation. PC software and USB connectivity are included for storage and performing the standard protocols. Features:- • Automatic ABI, TBI, PVR and segmental measurement • Automatic cuff inflation and deflation system • Guided step by step protocol • Large graphic LCD display • Uni-Directional 8 MHz Doppler Probe • PVR waveform • Photoplethysmography PPG Toe Sensor for TBI • Special Toe cuff is supplied • Separate mode for complete vascular profile study • Penile flow study • Gets connected on to any computer • Standards matching the International specification • Software for patient report generation & storage.

Send Message
product image
Pain & Woundcare Products

Neurolite Therapy is a medical device that emits infrared light at a wavelength of 890 nm along with LED light at a wavelength of 660nm, and can be applied to any area of the body, which may provide a relief for the patients. Neurolite Therapy device helps the patient if they can use early on to relieve pain, increase microcirculation, promote healing and relieve muscle spasm, it is possible to decrease pain levels, decrease the number of falls, the number of injuries and the necessity for amputations. It is also possible to increase the patient’s level of activities and quality of life, (due to reduction in pain) as well as overall patient compliance and satisfaction. Features: • Infra-red LED and RED led activated • Continuous or Pulsed operation • Increase vascular efficacy • Stimulate the production of collagen • Stimulate the release of adenosine tri-phosphate (ATP) • Stimulate fibroblastic activity • Stimulate tissue granulation and connective tissue projections • Stimulate acetylcholine release • Reduce the excitability of nervous tissue • Benefits Pain and Numbness in Extremities • Selective wavelengths for improved result • Built-in timer stops the therapy automatically • Stimulate the production of collagen • Increase lymphatic system activity • Stimulate tissue granulation and connective tissue projections

Send Message

Still searching for
enough sanitiser?