Chennai
+919382206047

'blood flow'

Items tagged with 'blood flow'

product image
Vascular Screening Products

The handheld Unidirectional ultrasound vascular Doppler is an instrument that detects blood flow using the principles of the Doppler effect. It can be a very useful tool in assessing how good the blood flow is to the foot or hand. It is a painless test and very similar to taking blood pressure using a stethoscope. It is particularly useful for the assessment of arterial disease but can also be used for venous problems. These vascular Doppler are used for identifying the arterial and venous flow patency. Ankle Brachial Index (ABI) is a simple procedure to detect obstruction in the blood flow. The LifeDop 150R features a non-display, handheld Doppler with superior sound quality, extended battery life, enhanced probe sensitivity, interchangeable probes, and a one-year full warranty. It includes a battery recharging system, so you don’t have to worry about overcharging or draining of the batteries. Features: • Interchangeable Doppler Probes • Unidirectional Doppler • 8MHz Vascular Probe is Standard • Continuous Wave Doppler • 4, 5 and 8 MHz Vascular probes • Rechargeable battery operation • Charger supplied free

Send Message
product image
Vascular Screening Products

Transcutaneous oxygen monitoring (TCOM / tcpO2) is a well-documented technique reflecting the nutritive flow in the capillaries. Today, TCOM / tcpO2 is commonly used in clinical applications such as wound-healing assessment, hyperbaric medicine, amputation-level determinations and more. Precise8001 offers the possibility to monitor the transcutaneous oxygen at the sites of interest. Features: • Fluorescence photo optical system and hence no membrane technology • No membrane and hence minimal operating cost • No pre-heating of sensor and self-automatic calibration while testing • Measurement time is less than 10 min • Automatic marking of end value • 10.1-inch large LCD touch screen Display • Displays the measurement process graphically and numerically • Integrated patient and measurement database • Oxygen partial pressure range of 0 to 2000 mmHg • Sensor temperature range 37 to 44 degree Celsius • Long enough 250cm(2.5meter) sensor cable for ease of placement • USB connection for Computer connection - Optional • Connects external memory for data transfer in txt format • Software for data transfer to computer - Optional • Standalone operation and operate with the computer if software purchased • Measurement is independent of skin pH and salt content • Weighs less than 3 kgs • Built-in rechargeable battery supports minimum 3 hours of operation • Unit works between 100Volts and 230Volts AC power supply • Truly portable

Send Message
product image
Podiatry Products

These Podiatry chairs were developed for a comfortable seated position for the client at all times. Its slender appearance makes the room or consultation area appear more spacious. In addition, the arms fold up completely, making it easy for the client to get in and out of the chair from the side. The leg supports of the chair are contoured and the height and length can be adjusted individually. Their ergonomic shape provides stable support for the lower leg and foot. PC303 - 3 function Podiatry Chair provides motorized adjustment of backrest, height and tilt using a hand remote control. PC305 - 5 function Podiatry Chair model inaddition to the PC303 model the leg rest right, left can also be adjusted individually by a motorized function.

Send Message
product image
Plantar Pressure Measurement Systems

The Podiascan system provides podiatrists and bio-mechanists with an economical and efficient method to measure static and dynamic plantar foot pressure distribution. The Podiascan system produces instantaneous and permanent high resolution image of the pressure distribution across the planter surface. We sell this product only in India. The Harris Mat paper output is scanned and the resultant grey scale image is converted into colour scale. Features : • System consists of Harris Mat, Special Scanner Copier and Printer, Image Analysis Software and Patient Reporting Software. • Economical method to measure Static and Dynamic Plantar foot pressure. • Qualitative multi-colour output makes the pressure reading easier. Used to Identify : • Areas of potential ulceration • Pre and Post surgical evaluation • Degree of pronation or supination • Weight bearing after surgery

Send Message
product image
Neuropathy Screening Products

One of the frequent causes of non-traumatic lower-limb amputation is Diabetes and is usually preceded by foot ulcer and infection. The reason of this ulceration is commonly a loss of protective sensation due to peripheral neuropathy, for which there is no prevention strategy. Current research promotes early detection of neuropathy so that secondary prevention measures, such as intensive foot-care education and treatment, can be used for individuals. In an effort to standardize and simplify the detection of insensate foot, the 5.07/10-gm Monofilament is recommended by the International Diabetes Federation and the World Health Organization as a device that can be used by health professionals at every level of care. A standardised filament is pressed against part of the foot. When the filament bends, its tip is exerting a pressure of 10 grams (therefore this monofilament is often referred to as the 10 gram monofilament). If the patient cannot feel the monofilament at certain specified sites on the foot, he/she has lost enough sensation to be at risk of developing a neuropathic ulcer.

Send Message

Still searching for
blood flow?