Items tagged with '37 to'

product image
Vascular Screening Products

Transcutaneous oxygen monitoring (TCOM / tcpO2) is a well-documented technique reflecting the nutritive flow in the capillaries. Today, TCOM / tcpO2 is commonly used in clinical applications such as wound-healing assessment, hyperbaric medicine, amputation-level determinations and more. Precise8001 offers the possibility to monitor the transcutaneous oxygen at the sites of interest. Features: • Fluorescence photo optical system and hence no membrane technology • No membrane and hence minimal operating cost • No pre-heating of sensor and self-automatic calibration while testing • Measurement time is less than 10 min • Automatic marking of end value • 10.1-inch large LCD touch screen Display • Displays the measurement process graphically and numerically • Integrated patient and measurement database • Oxygen partial pressure range of 0 to 2000 mmHg • Sensor temperature range 37 to 44 degree Celsius • Long enough 250cm(2.5meter) sensor cable for ease of placement • USB connection for Computer connection - Optional • Connects external memory for data transfer in txt format • Software for data transfer to computer - Optional • Standalone operation and operate with the computer if software purchased • Measurement is independent of skin pH and salt content • Weighs less than 3 kgs • Built-in rechargeable battery supports minimum 3 hours of operation • Unit works between 100Volts and 230Volts AC power supply • Truly portable

Send Message
product image
Diabetic Foot Evaluation Lab

Automated diabetic foot evaluation lab model Diabetik Autolab is capable of screening (1) Vascular Insufficiencies using Ankle Brachial Index, Toe Brachial Index, Velocity waveform analysis, (2) Diabetic neuropathy using loss of vibration perception threshold (VPT)-Biothesiometry and loss of protective touch sense-Monofilament 10gm, (3) plantar pressure screening using advance electronic sensor platform by checking static(weight bearing), dynamic(walking) and postural imbalance, (4) Non-contact measurement of temperature in the foot for early assessment of inflammation in the foot. A master report is generated with the patients clinical information, medical information and the measured data with interpretation. Device is supplied in a trolley and a branded i3 based laptop computer and an EPSON ink tank printer. Sales and service team across India to train the user periodically. ISO13485:2016 certified company.

Send Message
product image
Diabetic Neuropathy Products

Monofilaments MF10GM contain a small strand of filament attached to a visiting card-like handle. When placed upon the skin perpendicularly and applied an amount of pressure before the filament bends or buckles. The point at which the filament bends or buckles is rated in grams of force. 10gm Monofilament is widely accepted by the medical community and recommended by WHO and IDF for evaluating the loss of protective touch sense. The MF10GM Monofilament is intended to be used to determine whether a person with diabetes has the presence of an adequate level of protective sensation in their feet as indicated by having enough tactile sensitivity to perceive 10 grams of force against the skin of their feet. The monofilament is tested on multiple points on the foot of the person to be tested and they should feel the sense in the majority of the test points. If they don’t feel the sense in multiple spots, then it is indicated that they would have lost the protective touch sense. It should be used on adult Diabetic patients on a periodic basis to evaluate changes in sensory perception in the feet due to Diabetic peripheral sensory neuropathy. This device is not a complete replacement for routine sensory evaluation by a health care provider. They are available in a box of 25pcs and cost Rs. 650 inclusive of GST and Courier.

Send Message
product image
Vascular Screening Products

Vasochek+ is a complete non-invasive unidirectional vascular doppler recorder designed to measure the ABI, TBI and the velocity waveform with a connection to a windows 7/8/10 operated computer for storage of data and patient report generation. Interpretation as per TASC II guidelines. FEATURES: • Ankle Brachial Index and Toe Brachial Index • Doppler (C.W) with 8MHz Transducer • Photo-Plethysmography (PPG) Toe sensor • Semi-automated system • Software for ABI/TBI with Waveform • Computer connectivity enabled • Software for data transfer, storage and patient report • Software supports Windows 7/8/10 • Standards matching International standards

Send Message
product image
Podiatry Products

These Podiatry chairs were developed for a comfortable seated position for the client at all times. Its slender appearance makes the room or consultation area appear more spacious. In addition, the arms fold up completely, making it easy for the client to get in and out of the chair from the side. The leg supports of the chair are contoured and the height and length can be adjusted individually. Their ergonomic shape provides stable support for the lower leg and foot. PC303 - 3 function Podiatry Chair provides motorized adjustment of backrest, height and tilt using a hand remote control. PC305 - 5 function Podiatry Chair model inaddition to the PC303 model the leg rest right, left can also be adjusted individually by a motorized function.

Send Message
product image

Ambulatory blood pressure monitoring (ABPM) is being increasingly recommended for routine clinical practice. It may be particularly useful in evaluating the patient with variable blood pressure readings in the office, or the patient with wide discrepancies between the blood pressure readings at home and the clinician's office (ie, "white coat" hypertension). ABPM and, in particular, nocturnal blood pressure readings, may also provide prognostic data. Ambulatory blood pressure (ABP) monitoring involves measuring blood pressure (BP) at regular intervals (usually every 15–30 minutes) over a 24 hour period while patients undergo normal daily activities, including sleep. . What are the indications? • Suspected white-coat hypertension (including in pregnancy) • Suspected masked hypertension • Suspected nocturnal hypertension or no night time reduction in BP (dipping) • Hypertension despite appropriate treatment • Patients with a high risk of future cardiovascular events (even if clinic BP is normal) • Suspected episodic hypertension • Prolonged Diabetes Supplied with unit, Adult BP cuff, Wide BP cuff for obese patients and software.

Send Message
product image
Plantar Pressure Measurement Systems

The Podiascan system provides podiatrists and bio-mechanists with an economical and efficient method to measure static and dynamic plantar foot pressure distribution. The Podiascan system produces instantaneous and permanent high resolution image of the pressure distribution across the planter surface. We sell this product only in India. The Harris Mat paper output is scanned and the resultant grey scale image is converted into colour scale. Features : • System consists of Harris Mat, Special Scanner Copier and Printer, Image Analysis Software and Patient Reporting Software. • Economical method to measure Static and Dynamic Plantar foot pressure. • Qualitative multi-colour output makes the pressure reading easier. Used to Identify : • Areas of potential ulceration • Pre and Post surgical evaluation • Degree of pronation or supination • Weight bearing after surgery

Send Message
product image
Neuropathy Screening Products

One of the frequent causes of non-traumatic lower-limb amputation is Diabetes and is usually preceded by foot ulcer and infection. The reason of this ulceration is commonly a loss of protective sensation due to peripheral neuropathy, for which there is no prevention strategy. Current research promotes early detection of neuropathy so that secondary prevention measures, such as intensive foot-care education and treatment, can be used for individuals. In an effort to standardize and simplify the detection of insensate foot, the 5.07/10-gm Monofilament is recommended by the International Diabetes Federation and the World Health Organization as a device that can be used by health professionals at every level of care. A standardised filament is pressed against part of the foot. When the filament bends, its tip is exerting a pressure of 10 grams (therefore this monofilament is often referred to as the 10 gram monofilament). If the patient cannot feel the monofilament at certain specified sites on the foot, he/she has lost enough sensation to be at risk of developing a neuropathic ulcer.

Send Message
product image
Vascular Screening Products

The handheld Unidirectional ultrasound vascular Doppler is an instrument that detects blood flow using the principles of the Doppler effect. It can be a very useful tool in assessing how good the blood flow is to the foot or hand. It is a painless test and very similar to taking blood pressure using a stethoscope. It is particularly useful for the assessment of arterial disease but can also be used for venous problems. These vascular Doppler are used for identifying the arterial and venous flow patency. Ankle Brachial Index (ABI) is a simple procedure to detect obstruction in the blood flow. The LifeDop 150R features a non-display, handheld Doppler with superior sound quality, extended battery life, enhanced probe sensitivity, interchangeable probes, and a one-year full warranty. It includes a battery recharging system, so you don’t have to worry about overcharging or draining of the batteries. Features: • Interchangeable Doppler Probes • Unidirectional Doppler • 8MHz Vascular Probe is Standard • Continuous Wave Doppler • 4, 5 and 8 MHz Vascular probes • Rechargeable battery operation • Charger supplied free

Send Message