http://WWW.DIABETICFOOTCAREPRODUCTS.COM
DIABETIKFOOTCAREINDIA 54f19a0c4ec0a41ea8057c37 False 64 30
OK
background image not found
Found Update results for
'vascular efficacy stimulate fibroblastic activity wound healing'
9
IR Light Therapy NEUROLITE: IR LED Neurolite Therapy is a medical device that emits infrared light at a wavelength of 890 nm along with LED light at a wavelength of 660nm, and can be applied to any area of the body, which may provide a relief for the patients. Neurolite Therapy device helps the patient if they can use early on to relieve pain, increase microcirculation, promote healing and relieve muscle spasm, it is possible to decrease pain levels, decrease the number of falls, the number of injuries and the necessity for amputations. It is also possible to increase the patient’s level of activities and quality of life, (due to reduction in pain) as well as overall patient compliance and satisfaction. Features: • Infra-red LED and RED led activated • Continuous or Pulsed operation • Increase vascular efficacy • Stimulate the production of collagen • Stimulate the release of adenosine tri-phosphate (ATP) • Stimulate fibroblastic activity • Stimulate tissue granulation and connective tissue projections • Stimulate acetylcholine release • Reduce the excitability of nervous tissue • Benefits Pain and Numbness in Extremities • Selective wavelengths for improved result • Built-in timer stops the therapy automatically • Stimulate the production of collagen • Increase lymphatic system activity • Stimulate tissue granulation and connective tissue projections
Automated Vascular Doppler Recorder for ABI / TBI - VERSALAB Auto DFCI offers a full featured automated ABI / TBI Vascular System for the diagnosis of PAD. ABI / TBI / PVR / Segmental Doppler / Upper extremity / Carotid Doppler / Penile Doppler / Venous Doppler are the different modalities possible with this model. The system includes 6 pressure cuffs, a graphic waveform LCD display, Automatic BP Cuff inflation and deflation along with automatic indices calculation. PC software and USB connectivity is included for storage and performing the standard protocols. Features:- • Automatic ABI, TBI, PVR and segmental measurement • Automatic cuff inflation and deflation system • Guided step by step protocol • Large graphic LCD display • Uni-Directional 8 MHz Doppler Probe • PVR waveform • Photo plethysmography PPG Toe Sensor for TBI • Special Toe cuff is supplied • Separate mode for complete vascular profile study • Penile flow study • Gets connected on to any computer • Standards matching International specification • Software for patient report generation & storage.
Hand Held Vascular Doppler - LifeDop L150R Hand Held Vascular Doppler model LIFEDOP L150R, 8MHz works with rechargeable battery widely used for the screening of arterial and venous insufficiency. This vascular ultrasound is an easy tool to find the Ankle Brachial Index (ABI). Features :  Doppler Unidirectional 8 MHz transducer  ABI Doppler  Superior Sound Quality SSQ Audio output  Handy and portable pocket model  All arterial and venous examination of extremities  Interchangeable 4 & 5 MHz Doppler transducer option
Digital Biothesiometer cum Vascular Doppler – VIBRODOP This is a combined version of Biothesiometer VIBROMETER and Vascular Doppler VERSADOP Dx. Very useful entry level tool with computer connectivity and software for detecting Ankle Brachial Index(ABI) and VPT. This tool is also a proven tool for conducting large patient screening camp. It can be used simultaneously for Biothesiometry study and ABI study as well when used without Computer connection. Features: • 8 MHz unidirectional Doppler transducer • ABI cuff sets with manometer • Manual ankle brachial index study(TBI not measured) • Full solid state Design • Digital 0 to 50 Volts output indicator • Electronic Tuning Fork • Easy tool to quantify Neuropathy • Gets connected on to any computer • PC software for storage and printout • Works without PC connection also • Standards matching International specification • Light weight and portable
ABI Vascular Doppler - VERSADOP Dx The Versadop Dx is a simple vascular Doppler designed for the measurement of Ankle Brachial Index. It is compatible with PC and generates ABI reports. TBI measurement using PPG is not possible in this model. Features: • 8 MHz unidirectional Doppler transducer • ABI cuff sets with manometer • Manual ankle brachial index study • Gets connected on to any computer • PC software for storage and printout • Standards matching International specification • Light weight and portable
Non-Invasive Vascular Screening Device - VP1000 plus Using it's four cuff system the VP-1000plus quickly and simply assesses Ankle-Brachial Index (ABI) and Pulse Wave Velocity (PWV) providing highly valuable clinical information within minutes. The short time taken to complete the assessment and the fully automatic functionality make the VP-1000 ideal for Vascular clinics, Cardiology and General practice. Omron VP-1000 plus (Colin VP1000) Features: Fast - The Omron VP-1000 Measurement Process can take as little as 10 minutes to complete from start to finish Simple - Fully automated operation. Once the cuffs, ECG & PCG sensors are in place, the VP-1000 plus automatically completes the assessment with no further input from the clinician. Accurate and Reproducible - The 'Sensor Cuffs' measure arterial pressure and waveform, eliminating the need for hand-held probes, and hence eliminating investigator variability. Simultaneous Measurement of all limbs - The Omron VP-1000 simultaneously measures arterial pressures and waveform in all 4 limbs facilitating a highly accurate Ankle-Brachial Index calculation that isn't compromised by the passing of time between individual limb measurements done sequentially Touch Screen Interface - The Omron VP-1000's touch screen interface and logical menu system simplifies data entry and navigation Multiple Report Format Options - The Omron VP-1000 plus allows clinicians to select printed report formats that are most appropriate for their practice (Click on Printed Reports to view reports). Reports available include: Clinicians Report, Patient Report, Trend Report, Post Exercise/Recovery Report Portable - The Omron VP-1000 plus main unit can operate as a 'Bench Top' unit, separate from the roller stand and printer, and can be transported in a small case making it portable enough to take between clinics or consultation room Networkable - The Omron VP-1000 plus can be networked with major clinical management software packages, allowing simple data storage directly into patient files Toe Brachial Index (TBI) function - A 'TBI' function is available using plethysmographic toe cuffs that can detect arterial pulses in the toes
Vascular Doppler Recorder - VERSALABTM LE The Versalab LE is a Vascular Ultrasound Doppler system which is compatible with computer interface. It is a semi-automatic Doppler system that captures the Doppler and PPG waveforms and calculates ABI and TBI indices. It has a real-time waveform LCD and integrated printer for documentation required. • 8 MHz unidirectional Doppler transducer • Photo Plethysmography (PPG) for Toe Pressure measurement • 3 BP cuffs with manometer for ABI & TBI • Special Toe cuff is supplied • Manual BP measurement • Gets connected on to any computer • PC software for storage and printout on A4 size plain paper • Large LCD screen makes the measurement easy • Standards matching International specification • Light weight and portable
IR Foot Thermometer FT4 Inflammation is one of the earliest signs of tissue injury and ulceration. However, the clinical signs of inflammation are usually too subtle to be detected by patients or even by trained health care providers. We hypothesized that skin temperatures could be used as a surrogate measure of injury and localized inflammation. Skin temperature measurements can be easily performed and assessed by the lay public and have been used as a diagnostic tool for diabetic foot ulcerations The aim of this product is to help high-risk individuals identify areas on their feet that are inflamed and prone to ulceration before a wound develops. The patients to record foot temperatures in the great toe, the first, third, and fifth metatarsal head region, the midfoot, and the heel. If skin temperatures were elevated by >40F (2.20C) compared with the corresponding site on the opposite foot for two consecutive days, subjects were instructed to contact the hospital and decrease their activity until temperatures normalized. Software is supplied for storing the data in computer free of cost along with the instrument. Features : • Early marker for identifying foot ulcer • Simple One handed operation • 3.1/2 digit LCD with back light • Accuracy +/- 2 • Early marker for Charcot foot • Laser targeting • oC / oF select switch
PC Based Digital Biothesiometer & Vascular Doppler - VIBRODOP India’s first innovative design that has combined Biothesiometer for the detection of loss of vibration perception and Vascular Doppler for the measurement of Ankle Brachial India (ABI). Computer connectivity is a built-in facility and reports are generated by the software supplied. FEATURES: • Doppler (C.W) with 8MHz Uni-Directional probe • Ankle Brachial Index • Doppler Velocity Waveform with ABI Indices • 0 to 50 Volts Vibration linear output • Computer connectivity enabled • Software for data transfer, storage and patient report • Software supports all formats of Windows (Xp to Win8) OS • Standards matching International standards
1
false